Gloves

Showing all 5 results

All systems are: Real-time, Occlusion free, Solving free, Marker free (no swapping), and can be solo operated, and do not need a calibrated space to operate in.
Click here to see a video of the gloves
Click here to see an images of the sensor placement

Glove Comparison Table

GLOVE SYSTEM HARDWARE IGS-Glove-16 IGS-Glove-12 IGS-Glove-12Wired IGS-Glove-7 IGS-Glove-7Wired
Wireless Yes Yes No Yes No
IMU sensor type Osv5 Osv5 Osv5 Osv5 Osv5
Processing Module ILMPU* ILMPU* USB-CU with Host PC ILMPU* USB-CU with Host PC
Wired processing system included As well As well Yes As well Yes
Data Logging on-board Optional Optional N/A Optional N/A
Raw Data Optional Optional Available Optional Available
Serial System RS485 RS485 RS485 RS485 RS485
Data Processing On Sensors & On-Board ILMPU On Sensors & On-Board ILMPU On Sensors & Host PC On Sensors & On-Board ILMPU On Sensors & Host PC
Sync through other SW MB, Unity, Seimens MB, Unity, Seimens MB, Unity, Seimens MB, Unity, Seimens MB, Unity, Seimens
Sync using external time servers Through TCP Client SDK Through TCP Client SDK N/A Through TCP Client SDK N/A
Sync using TTL servers Through Optional HW Through Optional HW Through Optional HW Through Optional HW Through Optional HW
SDK UDP & TCP Client side UDP & TCP Client side UDP & TCP Client side UDP & TCP Client side UDP & TCP Client side
Set up Time (box to capture) 7 mins. 7 mins. 2 mins. 7 mins. 2 mins.
Battery lasting (hours) 2 2.5 N/A 4 N/A
Hot-Swapping Batteries Yes Yes N/A Yes N/A
Available finger segment channels 16 16 16 16 16
Number of sensors applied 16 12 12 7 7
Finger distals (4/hand) sensor measured extrapolated extrapolated extrapolated extrapolated
Fingers middles (4/hand) sensor measured sensor measured sensor measured sensor measured sensor measured
Finger proximals (4/hand) sensor measured sensor measured sensor measured Interpolated Interpolated
Thumb metatacarpal (1/hand) sensor measured sensor measured sensor measured Interpolated Interpolated
Thumb distal & proximal (2/hand) sensor measured sensor measured sensor measured sensor measured sensor measured
Palm sensor measured sensor measured sensor measured sensor measured sensor measured
User calibration SW & HW Provided to use as necessary Provided to use as necessary Provided to use as necessary Provided to use as necessary Provided to use as necessary
Kinematic hand skeleton Once per subject and saved Once per subject and saved Once per subject and saved Once per subject and saved Once per subject and saved
SW to calibrate hand skeleton Included Included Included Included Included
Practical Roaming Range 20 Meters 20 Meters 2 Meters (or roam with Laptop) 20 Meters 2 Meters (or roam with Laptop)
Outdoor Capture Need Laptop Need Laptop Need Laptop & optional battery Need Laptop Need Laptop & optional battery
Data cleaning Minimal Minimal Minimal Minimal Minimal
Sensor placement routine Wear glove, adjust in one axes Wear glove, adjust in one axes Wear glove, adjust in one axes Wear glove, adjust in one axes Wear glove, adjust in one axes
Cloth Housing Various sizes optional Various sizes optional Various sizes optional Various sizes optional Various sizes optional
Change housing cloth 10 mins. 10 mins. 10 mins. 10 mins. 10 mins.
Can move electronics from L to R Yes Yes Yes Yes Yes

 


Sensor Placement Comparison


7 Sensor

12 Sensor

16 Sensor

Select a glove model to show sensor placement